- 4 -
Fig. 1.2 DIMENSIONS (in)
The specifications and dimensions are listed as follows:
Model Exhaust CFM
Cabinet Size
(cu ft)
Electrical Weight (lb)
WM-
1500htd
Rear Exhaust
120 90 115V/60Hz/4A 55
WM-
1500htd-te
Top Exhaust 120 90 115V/60Hz/4A 55
WM-
2500htd
Rear Exhaust 180 200 115V/60Hz/5A 60
WM-
2500htd-te
Top Exhaust 180 200 115V/60Hz/5A 60
NOTES:
Also see the voltage, frequency and current specified on the label at the
cooling unit.
The rated capacity is determined under the cabinet and ambient
temperatures of 55
°F and 75°F with R13 interior and R19 exterior
insulations. Any lower cabinet temperature, higher ambient temperature
and less insulation will cause reducing capacity and may not maintain
55
°F.
The ambient temperatures for WM-1500HTD shall not be higher than
78
°F or lower than 50°F in order to operate properly.
The ambient temperatures for WM-2500HTD shall not be higher than
95°F or lower than 50°F in order to operate properly.